Regenerative Care Pricing, Built for the ODs on Finance Network — Amniotic Membrane Therapy
ODs on Finance × Ophthalogix
Regenerative Care Pricing, Built for the ODs on Finance Network — Amniotic Membrane Therapy
Members Only
Exclusive member benefits, streamlined ordering, and direct clinical support for ODs on Finance practices.
Member Pricing
Preferred rates across Aurora & Eclipse
FDA HCT/P Compliant
AATB-accredited processing, every batch
Clinical Support
Direct line to our clinical team
Fast Fulfillment
Ships same or next business day
Regenerative Care for the Ocular Surface
Amniotic membrane provides a biologic matrix containing growth factors, cytokines, regulatory proteins, and extracellular matrix components that support ocular-surface healing and regeneration.
Common Optometric Applications
Dry Eye Syndrome
Superficial Keratitis
Recurrent Corneal Erosion
Corneal Ulcer
Easy to Integrate Into Your Practice
AMT can be incorporated into existing anterior-segment and ocular-surface workflows, giving doctors another treatment option for appropriate patients when regenerative support is clinically indicated.
Better Tissue. Smarter Design. Complete Practice Support.
Biologically Active
FORMULA/5™ processing preserves native growth factors and extracellular matrix components that support ocular-surface healing.
Aurora Clear-Center Design
Aurora's patent-pending 5 mm central aperture maintains the central visual axis during treatment, helping reduce visual obstruction associated with full-coverage membranes.
5-Year Shelf Life
Room-temperature storage with no refrigeration or cold-chain management required.
Clinical + Practice Support
Support with product selection, application guidance, staff training, patient selection, documentation, coding resources, and practice integration.
Direct Clinical Access
Access to the Ophthalogix clinical team for product selection, application questions, case discussions, and follow-up support.
$1,295 National Average Reimbursement
No Global Period
Reimbursement varies by payer, geographic location, coverage policy, and individual patient circumstances. Providers are responsible for verifying coverage and reimbursement.
Full CPT & billing guide →Which product is right for the case in front of you?
| Aurora | Eclipse | |
|---|---|---|
| Primary clinical applications | Dry eye disease, neurotrophic keratitis, persistent epithelial defects, post-surgical surface repair | Corneal and conjunctival applications across a broad range of defect sizes |
| Central aperture vs. full coverage | Circular with 5 mm central aperture | Circular, full coverage |
| Available sizes | 10 mm / 12 mm disc | 5, 8, 10, 12, 14, 16 mm |
| Visual function during treatment | Maintained — central aperture keeps the visual axis clear | Reduced over the defect area |
| Shelf life | 5 years | 5 years |
When to choose Aurora
Choose Aurora when preserving the patient's central vision during in-office treatment matters — its 5 mm central aperture keeps the visual axis clear for dry eye disease, neurotrophic keratitis, persistent epithelial defects, and post-surgical surface repair.
When to choose Eclipse
Choose Eclipse when you need one product line across the full range of corneal and conjunctival defect sizes — six diameters cover everything from routine office cases to O.R. reconstruction.
Before & after, from real Ophthalogix practices.
Member Pricing
Preferred per-unit pricing across the full Aurora and Eclipse product lines, exclusively for ODs on Finance member practices.
Streamlined Ordering
Add products to your cart and check out directly on this page — no new account required.
Dedicated Clinical Support
Direct access to the Ophthalogix clinical team for product selection, application technique, and post-application questions.
Fast Fulfillment
Tracked shipping via FedEx. Shipping occurs on same business day if order is placed before 3:00 CST. After that, it is shipped on the next business day.
Exclusive ODs on Finance pricing on Aurora and Eclipse, shown below. Pick a size or format, then add it to your order.
This is promotional pricing for orders made through ODs on Finance. Pricing is subject to change. All orders are subject to shipping fees.
Aurora
Single-layer AMT with a patent-pending central aperture.
Eclipse
Single-layer AMT in four diameters, for office and O.R. use.
Backed by results, not just claims.
“I've been using amniotic membrane treatments for years, and they've consistently given great results for my patients. Healing time has been smoother, irritation improves quickly, and overall patient comfort is much better.”
“As someone who manages a busy clinic, amniotic membrane treatments have been a great addition to our practice. Patients respond really well to them, and we've seen consistently positive results over the years.”
Schedule a consultation.
Book time with the Ophthalogix clinical team to review product selection, application technique, or your practice's first case.
Pick a time that works for you — you'll get an instant confirmation by email.
Questions? We're here.
Reach the Ophthalogix team directly — no ticket queue, no runaround.